73 — Graphing statistics
Alcatel-Lucent 5620 Service Aware Manager, Release 7.0 R6 December 2009 73-3
3HE 04551 AAAE Ed. 01 Statistics Management Guide
Configuration panel
The configuration panel identifies the objects and statistics counters in a graph. You
can enter up to four counters in this panel. If more than one counter from the same
monitored object is required, you can click on the Duplicate button and choose the
new counter and class. After you choose the counters, you can close the panel to
increase the space available for the graph panels. The Configuration panel contains
the following columns:
• Marker—displays the data points as markers in the detail panel
• Plot Name—identifies the plots in the graph
• Y Axis—allows you to choose Y Axis 1 or Y Axis 2. See “Choosing the Y-axis”
in this section for more information
• Monitored Object—lists the monitored objects
• Statistics Group—allows you to choose the statistics class for the object
• Statistics Counter—allows you to choose the statistics counter for the object.
See “Statistics counters” in this section for more information
Detail panel
The detail panel contains the plotted statistics line graphs. The panel can contain
historical or real-time graphs, but not both.
The real-time graphs start collection after the plotter opens. The historical graphs use
the data stored in the 5620 SAM database. You can zoom in and zoom out on a graph,
and for real-time statistics, you can enable or disable automatic scrolling.
See “Overview panel” in this section for more information.
You can enable or disable the markers and legend for a graph, and can save a graph
with or without the legend or markers. Markers are useful for identifying different
lines, for example, when a graph is printed in black and white. You can enable or
disable the X, Y1, and Y2 grid lines. The Y1 and Y2 grid lines are displayed only
when the corresponding Y axis is in use. See Procedures 73-2 and 73-3 for more
information.
Overview panel
The overview panel displays a high-level view of the plot data. The shaded box in
the panel contains the statistics that are displayed in the detail panel. When you
double-click on the box, you toggle automatic scrolling on or off. The box is green
when automatic scrolling is enabled, and red when it is disabled. You can click on
the box and drag it horizontally to change the display in the detail panel. When the
box is not selected and real-time statistics are being plotted, the box autoscrolls to
show the latest statistics. When automatic scrolling is disabled, the detail panel
remains in the location shown in the red box.
Data panel
The data panel displays a table of the collected statistics values. The statistics can be
saved in CSV or HTML format. See chapter 3 of the 5620 SAM User Guide for
information about using the contextual menu in the plot value list heading.