Carrier 50PG03-07 Dokumentacja Strona 44

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 43
FIELD-- _I_BLK
POWER _ . : YEt --
SUPPLY _" I BLU--
--I± I- -- -[_[E]
II I EOUIP GND
I L _ " - BOX_
_ -F]OPIACCESSORY
: ELE ,R=<NE=T
[ "=="==,ISR T'ON
_IELD_---- _---'-q
SUPPLY W
GNit -- --
: N(_ "
TRANI
,--REDaN,-
TOCBI TO 24V
(32 AMPS} CHEMATIC
LEGEND
AHA -- Adjustable Heat Anticipator
AL -- Ambient Lockout
--A -- Circuit A
C -- Compressor Contactor
CAP -- Capacitor
DB -- Circuit Breaker
CC -- Cooling Compensator
CCH -- Crankcase Heater
CCHR -- Crankcase Heater Relay
COHS -- Crankcase Heater Switch
CLO -- Compressor Lockout
COMP -- Compressor
CT BRK -- Circuit Breaker
ECB -- Economizer Control Board
ECON -- Economizer
FlOP -- Factory-lnstaRed Option
FPT -- Freeze Protect Thermostat
FS -- Flame Sensor
FU -- Fuse
GND -- Ground
GV -- Gas Valve
HACR -- Heating, Air Conditioning,
and Refrigeration
HPS -- High-Pressure Switch
I -- Ignitor
IAE -- Indoor Air Enthalpy
IAQ -- Indoor Air Quality
IBM -- Induced-Draft Motor
IFC -- Indoor-Fan Contactor
IFM -- Indoor-Fan Motor
IGC -- Integrated Gas Controller
LOR -- Lockout Relay
LPS -- Low-Pressure Switch
LS -- Limit Switch
LSM -- Mechanical Limit Switch
OAE -- Outdoor-Air Enthalpy
OAS -- Outdoor-Air Sensor
OFM -- Outdoor-Fan Motor
O/ -- Overload
PEC -- Power Exhaust Contactor
PEM -- Power Exhaust Motor
PL -- Plug
PLP -- Phase Loss Protection
QT -- Quadruple Terngnal
BAR -- Return Air Sensor
SAT -- Supply-Air Temperature
TB -- Terminal Block
TC -- Thermostat-Cooling
TDR -- Time Delay Relay
TH -- Thermostat-Heating
TRAM -- Transformer
@ Terminal (Marked)
O Terminal (Unmarked)
_ Terminal Block
Factory Wiring
Field Control Wiring
Field Power Wiring
.... Accessory or Optional Wiring
To Indicate Common Potential
Only. Not to Represent Wir-
ing.
CLOAI
rffn
COMPAI
_v_ CCHAI
itLR-
YEL- IFM
(05 ALT,
STit)
CAPR
LK
o--itLH_
BRN IFM
104 STD,ALT,
fEL 05 STD)
OPM
itLN #R
PL2-5
_YEL )
-t-itLU 0
I ROP/ACCE550RY
POWERE_IAUST
YEL-_ _it RN -_, }%RN/q "
itLit 'EL|I
IL_ FCD--ItRN-+'_FORN':L
L< itLu_ YEL-I
PEER
YEL
TRAN 6 C_
PR,.=.:=i!oi:ii)oli '
WIRING
: I = itLN_
DFqI
Fq
1211
MO4-M06
PAC ONLY
CAP3
itRN IDM
YEL
TIC
v Nrn
@[Ngn
GAS SECTION ONLY
(48 SERIES)
ELECTRIC HEAT ONLY
(50 SERIES)
THERMOSTAT/IGC MARKINGS
BM -- Blower Motor L1 -- Line 1 W2 -- 2nd Stage of Heating
C -- Common R -- Thermostat Power X -- Alarm Output
CM -- Combustion Motor BT -- Power Supply Y1 -- 1st Stage of Cooling
CS -- Centrifugal Switch SS -- Speed Sensor Y2 -- 2nd Stage of Cooling
G -- Fan W -- Thermostat Heat
IFO -- Indoor Fan On Wl -- 1st Stage of Heating
NOTES:
1. If any of the original wire furnished must be replaced, it must be replaced with type 90° C or its equivalent.
2. Three phase motors are protected under primary single phasing conditions.
3. Use copper conductors only.
4. RED jumper wire must be added between R and Wl for Space Temperature mode and temporarily during Ser-
vice Test mode when the heaters need to operate.
5. TRAM1 and 2 are wired for 230 v on 208/230 v units. If unit is to be run with 208 v power supply, disconnect BLK
wire fR)m 230 v terminal and connect to 200 v terminal.
Fig. 32 -- Typical Power Schematic
44