Design flexibility
The 48/50N Series rooftop units with
ComfortLink controls are designed to
meet all customer requirements for
new construction, replacement jobs, or
special applications. The customer can
choose from the following:
standard or high efficiency options
standard or high capacity options
CV, SAV™ or VAV applications
double wall foam panel construction
with optional Agion
®
interior
optional digital scroll compressors
supply-fan motor sizes from 15 to
100 hp
open drip proof (ODP) or totally
enclosed fan cooled (TEFC) motors
up to 4 sizes of natural gas heat with
optional modulating control (48
Series units)
3 sizes of electric heat with optional
SCR (silicon controlled rectifier)
control (50 Series units)
hydronic heat with modulating con-
trol (50 Series units)
microchannel heat exchanger
(MCHX) condenser coils or e-coated
MCHX condenser coils
integrated economizer with ultra
low-leak dampers per AMCA (Air
Movement and Control Associa-
tion) Std 500
modulating power exhaust or return
fan
optional low outdoor sound configu-
ration
mixed air and final filter options
including pleated, bag, cartridge and
HEPA (high efficiency particulate
air) types
Humidi-Mizer
®
adaptive dehumidifi-
cation system
optional auxiliary coil section or
blank sections in 4 or 8 ft lengths
Supply/return configurations
The units may be provided with vertical
or horizontal supply, vertical or hori-
zontal return, in any combination, e.g.,
horizontal supply with vertical return.
Exhaust and return options — Su-
perior space pressure control is provid-
ed by specifying one of the modulating
power exhaust systems. Modulating
power exhaust systems utilize a vari-
able frequency drive (VFD) to control
exhaust fan airflow rates to maintain a
user-established space pressure set
point. The power exhaust options in-
clude high and low static choices with a
wide range of motor horsepower avail-
able. For applications with ducted re-
turns that have significant duct static
pressures an optional return fan and
building pressure control exhaust sys-
tem is available. The return fan pro-
vides a separate fan system dedicated
to overcoming flow losses in the return
duct, thus reducing the total selection
load on the unit's supply fan. The re-
turn fan option includes a VFD which
modulates return fan airflow to match
supply fan airflow and to provide high
exhaust flow rate.
Efficiency/capacity options — The
customer is given the opportunity to
select the unit configuration that most
closely matches the application re-
quirements. Standard efficiency units
offer efficiency levels that exceed
ASHRAE 90.1 requirements and will
meet the needs of many applications.
For the energy conscious customer the
high efficiency units provide efficiency
levels that meet or exceed the Consor-
tium for Energy Efficiency (CEE) Tier 2
specifications. Standard and high ca-
pacity options allow the user to select
the capacity combination most appro-
priate for the application. The ability to
select efficiency and capacity levels will
provide up to four different unit combi-
nations in each unit size. In addition,
all motors are premium efficiency de-
signs and are VFD controlled to opti-
mize energy usage.
Environmentally sound
Carrier's Puron
®
refrigerant (R-410A)
enables you to make an environmen-
tally responsible decision. Puron refrig-
erant (R-410A) is an HFC refrigerant
that does not contain chlorine that is
damaging to the stratospheric ozone
layer. Puron refrigerant (R-410A) is un-
affected by the Montreal Protocol. Pu-
ron refrigerant (R-410A) is a safe, effi-
cient and environmentally sound refrig-
erant for the future.
Quality and reliability
The unit cabinet is constructed of dou-
ble wall foam panels for the sides, floor
and ceiling of the airside section. The
foam panels provide excellent insulat-
ing properties, structural rigidity and
easily cleaned surfaces. The entire unit
is supported on roll formed high
strength steel base rails. These rails of-
fer a stable base for the rooftop units
various components, e.g., compres-
sors, coils, and side panels. In addition
the continuous rail design provides a
strong lifting platform to allow easy
placement of even the largest units.
Performance
Excellent full and part load efficiencies
are achieved by using multiple scroll
compressors and indoor coils with in-
tertwined dual refrigerant circuits. En-
hanced refrigerant control is achieved
through the use of electronic expan-
sion valves (EXV). This enhanced con-
trol allows maximum utilization of the
Puron refrigerant and contributes to
improved efficiency. The compres-
sors are equipped with crankcase
heaters and protected by electronic
sensors and logic to control minimum
on and off times and reverse rotation.
The refrigerant circuits are both elec-
trically and mechanically independent,
to provide standby capability should
one circuit require service.
Features/Benefits (cont)
Table of contents
Page
Features/Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-7
Model Number Nomenclature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8,9
Ratings and Capacities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-12
Physical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13-23
Options and Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24-27
Base Unit Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28-35
Accessory Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36-40
Performance Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41,42
Electrical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44-52
Application Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53,54
Typical Piping and Wiring. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
Typical Wiring Schematics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56-70
Guide Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71-92
*Sponsored by ASHRAE (American Society
of Heating, Refrigerating, and Air Condition-
ing Engineers).
†Registered trademark of Schneider Electric.
**Registered trademark of Echelon
corporation.