COOLING PERFORMANCE
Model
Cooling Outdoor conditions (DB)
Indoor Conditions DB
75F(24C) 85F(29.5C) 95F(35C) 105F(40.5C)
DB WB
18
69.8F(21C) 59F(15C)
TC 18.07 18.74 17.22 13.28
SC 15.00 15.37 14.64 13.01
Input 1.17 1.54 1.72 1.88
80.6F(27C) 66.2F(19C)
TC 20.75 21.48 20.43 16.42
SC 15.97 16.33 15.93 14.62
Input 1.16 1.56 1.76 1.59
27
69.8F(21C) 59F(15C)
TC 23.99 27.20 24.55 19.31
SC 22.67 24.08 22.56 19.31
Input 1.50 2.42 2.67 2.39
80.6F(27C) 66.2F(19C)
TC 27.40 31.78 29.90 23.85
SC 23.72 25.06 2.51 22.94
Input 1.51 2.52 2.83 2.51
36
69.8F(21C) 59F(15C)
TC 28.80 32.69 30.25 23.15
SC 26.32 28.18 27.02 23.15
Input 2.17 3.45 3.81 2.99
80.6F(27C) 66.2F(19C)
TC 33.47 38.11 36.60 28.42
SC 28.83 30.55 32.94 26.99
Input 2.21 3.57 3.94 3.25
48
69.8F(21C) 59F(15C)
TC 44.06 42.04 38.95 34.05
SC 37.89 36.57 35.44 33.37
Input 3.32 3.78 4.19 4.45
80.6F(27C) 66.2F(19C)
TC 46.88 49.74 45.99 41.31
SC 40.32 43.27 41.85 40.07
Input 2.64 3.90 4.33 4.61
LEGEND
DB --- Dry Bulb
WB --- Wet Bulb
TC --- Total Net Cooling Capacity (1000 Btu/hour)
SC --- Sensible Capacity (1000 Btu/hour)
Input --- Total Power (kW)
HEATI NG PERFORMANCE
Model
Heating Outdoor conditions (DB)
Indoor Conditions (DB) 57F(13.9C) 47F(8.3C) 35F(1.7C) 17F(-8.3C) 5F(-15C) -5F(-20C)
18
55F(12.7C)
TH 23.27 20.85 16.80 13.29 10.92 8.63
Input 1.25 1.33 1.30 1.42 1.35 1.31
70F(21.1C)
TH 21.69 20.19 16.19 12.32 9.09 7.70
Input 1.45 1.51 1.49 1.56 1.48 1.41
27
55F(12.7C)
TH 37.85 34.34 28.36 22.77 19.38 16.23
Input 2.27 2.29 2.29 2.46 2.44 2.40
70F(21.1C)
TH 36.29 3.23 27.54 20.09 16.37 13.42
Input 2.68 2.64 2.51 2.53 2.39 2.29
36
55F(12.7C)
TH 41.10 38.52 28.84 28.16 22.87 19.43
Input 3.17 3.31 2.92 3.22 2.97 2.91
70F(21.1C)
TH 40.86 38.83 29.89 26.02 20.15 16.70
Input 3.62 3.73 3.37 3.38 3.05 2.90
48
55F(12.7C)
TH 60.91 53.30 42.81 33.02 26.16 20.01
Input 4.26 4.04 3.78 3.82 3.56 3.42
70F(21.1C)
TH 55.22 50.58 40.56 31.81 23.48 17.17
Input 4.64 4.59 4.20 4.27 3.98 3.88
LEGEND
DB --- Dry Bulb
TH --- Total Net Heating Capacity (1000 Btu/hour)
Input --- Total Power (kW)
Przeglądanie stron 17
1 2 ... 13 14 15 16 17 18 19 20 21 22 23 ... 35 36

Komentarze do niniejszej Instrukcji

Brak uwag

MULTIQUIP QP2E Handbücher

Bedienungsanleitungen und Benutzerhandbücher für Spielzeug & Zubehör MULTIQUIP QP2E.
Wir stellen 1 PDF-Handbücher MULTIQUIP QP2E zum kostenlosen herunterladen nach Dokumenttypen zur Verfügung Spezifikationen






Weitere Produkte und Handbücher für Spielzeug & Zubehör MULTIQUIP

Modelle Dokumententyp
Essick Series Spezifikationen   MULTIQUIP Essick Series Specifications [en] , 84 Seiten
EM120P series Spezifikationen   MULTIQUIP EM120P series Specifications, 48 Seiten