Software Revs 3,5,6,8,10, 12 Infinity /Evolution Troubleshooting (Rev. 2)
10-12-2006
8
User Interface Generated Fault Descriptions
Fault
Description
User Interface Display Action
Original
Models
-A models
Onboard
temp/humidity
sensor error
NO SENSOR
DATA on main
screen
TEMP/HUMIDITY
SENSOR FAULT
Sensor on User Interface has failed.
Replace User Interface or use remote
sensor for zone 1
Blower cutback
from indoor unit
EXCESS STATIC PRESSURE in fault
history
No error displayed on main screen
Max RPM was reached due to high
static pressure. In cooling and heat
pump heating, the airflow will step
down in an attempt to maintain system
operation. In furnace heating, if
minimum airflow cannot be achieved,
the Zoning Control will dump air where
possible or shut down the furnace
until more zones call for heat. In non-
zoned systems, the UI will not shut the
equipment down. See details in next
section.
Remote Room
Sensor failed
ZONE SENSOR
in fault history NO
SENSOR DATA
on main screen
for that zone
REMOTE SENSOR
FAULT in fault history
NO SENSOR DATA on
main screen for that
zone
Check wiring and ohm out sensor.
Smart sensor
zone x
communication
fault
SMART SENS ZONEx COMM in fault history
NO SENSOR DATA on main screen for that
zone
System cannot communicate with
smart sensor. Check bus voltages and
wiring.
Indoor unit
communication
fault
IDU COMM
FAULT in fault
history
CRITICAL
MALFUNCTION
on main
INDOOR UNIT
COMMUNICATION
FAULT in fault history
SYSTEM
MALFUNCTION on
main screen
User interface has lost communication
with indoor unit. Check voltages and
wiring. Perform communication bus
troubleshooting procedure shown on
page 21.