Software Revs 3,5,6,8,10, 12 Infinity /Evolution Troubleshooting (Rev. 2)
10-12-2006
3
User Interface generated Critical Malfunctions:
No communication with indoor unit
System Malfunction
Certain system events can result in the pop-up message “SYSTEM MALFUNCTION CALL TECHNICIAN”.
A system malfunction is an event that could be related to a failed component, or an event that may not
necessarily indicate an equipment problem. If this message clears on its own and the equipment operates
normally, it should be ignored. If it does not clear, or comes back repeatedly after being dismissed, the
system should be checked at the owner’s earliest convenience.
The user can press the right side button to dismiss the notice. The regular run mode screen will then
appear except “SYSTEM MALFUNCTION” will appear in place of the day/time. If the error has not
disappeared within 24 hours, the above display will return.
If the error code disappears, “SYSTEM MALFUNCTION” will disappear and the day/time will reappear.
This message may be generated from any of the communicating system components, and will be
displayed as shown in Figure 2. The following events may generate this message:
Fan Coil generated System Malfunction events:
Code 37 – Heater output sensed On when not energized (User interface will only display the pop-up
message, modifications to fan/staging operation will not occur)
Code 44 – Motor Communication Fault (version 10)
Code 41 – Blower Motor Fault (version 10)
Furnace generated System Malfunction events:
Code 13 – Limit Circuit Lockout
Code 14 – Ignition Lockout
Code 21 - Gas Heating Lockout
Code 22 - Abnormal Flame Proving Signal
Code 23 – Pressure Switch Did Not Open
Code 24 – Secondary Voltage Fuse Open
Code 33 – Limit Circuit Fault AND high heat only is active
Code 45 – Control Circuitry Lockout
Code 41 – Blower Motor Fault ((-A) models only)
2-Stage outdoor unit generated System Malfunction events (38TDB, YDB,
598B, 698B):
-VC VOLTAGE AT STANDBY (versions 8 and earlier)
-HI CAPACITY COMPRESSOR LOCKOUT (versions 8 and earlier)
FAN: AUTO
CALL TECHNICIAN
OUTSIDE: 94
o
SYSTEM MALFUNCTION
JOE'S HVAC SERVICE
(317) 555-1234
NOTICE >
DISMISS
Komentarze do niniejszej Instrukcji