Product Data
40MB*C / 38MAQ
Cassette Ductless Split System
Sizes 09 to 18
INDUSTRY LEADING
FEATURES / BENEFITS
A PERFECT BALANCE BETWEEN
BUDGET LIMITS, ENERGY SAVINGS AND
COMFORT.
The 38/40MB*C series ductless split systems are a matched
combination of an outdoor condensing unit and an indoor fan coil
unit connected only by refrigerant tubing and wires.
The in- ceiling cassette fan coils are ideal for retrofit or
modernization projects where a false ceiling is available. This
selection of fan coils permits inexpensive and creative solutions to
design problems such as:
S Add- ons to current space (an office or family room
addition)
S Special space requirements
S When changes in the load cannot be handled by the
existing system.
S When adding air conditioning to spaces that are heated
by hydronic or electric heat and have no ductwork.
S Historical renovations or any application where
preserving the look of the original structure is essential.
The ideal compliment to your ducted system when it is impractical
or prohibitively expensive to use ductwork.
These compact indoor fan coil units take up very little space in the
room and do not obstruct windows. The fan coils are attractively
styled to blend with most room decors. Advanced system
components incorporate innovative technology to provide reliable
cooling performance at low sound levels.
Przeglądanie stron 0
1 2 3 4 5 6 ... 18 19

Podsumowanie treści

Strona 1 - Product Data

Product Data40MB*C / 38MAQCassette Ductless Split SystemSizes 09 to 18INDUSTRY LEADINGFEATURES / BENEFITSA PERFECT BALANCE BETWEENBUDGET LIMITS, ENERG

Strona 2

10COOLING PERFORMANCE DATAModelCooling Outdoor conditions (DB)Indoor Conditions77F(25C) 86F(30C) 95F(35C) 104F(40C) 113F(45C) 122F(50C)DB WB09(208-230

Strona 3 - MODEL NUMBER NOMENCLATURE

11HEATING PERFORMANCE DATAModelHeating Outdoor conditions (DB)Indoor ConditionsDB53.6F(12C) 44.6F(7C) 39.2F(4C) 32F(0C) 24.8F(-4C) 19.4F(-7C) 17F(-8C)

Strona 4 - OUTDOOR UNITS

12APPLICATION DATAUNIT SELECTIONSelect equipment to either match or be slightly less than anticipatedpeak load. This provides better humidity control,

Strona 5 - DIMENSIONS - INDOOR

13WIRINGRecommended Connection Method for Power a nd Communi-cation Wiring (To minimize communication wiringinterfer-ence)Power Wiring:The main power

Strona 6 - DIMENSIONS - OUTDOOR

14AIR FLOW DATASYSTEM SIZECASSETTE9K 12K 18KHIGH 380 400 420MEDIUM 320 340 350LOW 260 280 290OUTDOOR (CFM) 945 945 1050SOUND PRESSURESYSTEM SIZECASSET

Strona 7 - CLEARANCES - INDOOR

15FAN AND MOTOR SPECIFICATIONSSystem sizeCassette9K 12K 18KIndoor fanmaterial ABS ABS ABSType LX-322*147.5*12-7N LX-322*147.5*12-7N LX-322*147.5*12-7N

Strona 8 - CLEARANCES - OUTDOOR

16WIRING DIAGRAMSFig. 6 – Wiring Diagram 38MAQB09- - - 3 / 40MBQ09C- - 3 AND 38MAQB12- - - 3 / 40MBQ12C - - 3Indoor unit Outdoor unitCODE PART NAME CO

Strona 9 - SPECIFICATIONS

17Fig. 7 – Wiring Diagram 38MAQB18- - - 3 / 40MBQ18C- - 3Indoor unit Outdoor unitCODE PART NAME CODE PART NAMECN1Input: 230VAC High voltage Connection

Strona 10 - COOLING PERFORMANCE DATA

18GUIDE SPECIFICATIONSINDOOR CASSETTE DUCTLESS UNITSSize Range: 3/4 to 1 1/2 T on Nominal Cooling and Heating CapacityCarrier Model Number: 40MB*CPART

Strona 11 - HEATING PERFORMANCE DATA

19GUIDE SPECIFICATIONSHORIZONTAL DISCHARGE OUTDOOR UNITSSize Range: 3/4 to 1 1/2 T on Nominal Cooling and Heating CapacityCarrier Model Number: 38MAQP

Strona 12 - APPLICATION DATA

2LOW SOUND LEVELSWhen noise is a concern, the ductless split systems are the answer.The indoor units are whisper quiet. There are no compressorsindoor

Strona 13 - WIRELESS REMOTE CONTROL

3MODEL NUMBER NOMENCLATUREBQCMAXIMUM NUMBER OF FAN COIL UNITS THATCAN BE CONNECTED TO THE OUTDOOR UNITB=1:1SYSTEM TYPEQ =HEATPUMPNOT USEDINDOOR UNIT40

Strona 14 - SOUND POWER

4STANDARD FE ATURES AND ACCESSORIESEase Of InstallationMounting Brackets SLow Voltage Controls SComfort FeaturesMicroprocessor Controls SWired Remote

Strona 15 - FAN AND MOTOR SPECIFICATIONS

5DIMENSIONS - INDOORFig. 1 – Indoor unitUnit size9K 12K 18Kbody panel body panel body panelDimensionsHeight in(mm) 10.24 (260) 1.97 (50) 10.24 (260) 1

Strona 16 - WIRING DIAGRAMS

6DIMENSIONS - OUTDOORFig. 2 – Outdoor unitModel W in (mm) D in (mm) H in (mm) L1 in (mm) L2 in (mm)OperatingWeight lb (kg)9K/12K 32.0 (810) 12.2 (310)

Strona 17

7CLEARANCES - INDOORFig. 3 – Indoor Unit Clearance

Strona 18 - GUIDE SPECIFICATIONS

8CLEARANCES - OUTDOORADBAir-outletAir-inletCEFig. 4 – Clearances OutdoorUNITMinimum Valuein. (mm)A 24 (609)B 24 (609)C 24 (609)D 4 (101)E 4 (101)

Strona 19

9SPECIFICATIONSCarrier Cassette - Heat Pump (MB*C Series)SystemSize 9 12 18Outdoor Model 38MAQB09---3 38MAQB12---3 38MAQB18---3Indoor Model 40MBQB09C-