COOLING PERFORMANCE DATA -- 38/40MFC (COOLING ONLY)
Model
38---40MFC
Cooling Outdoor conditions (DB) ° F
Indoor Conditions
DB/WB ° F
(BTU/h) 77 86 95 104 113 122
009
69.8/59
TC 5.71 7.90 8.88 7.45 6.20 5.18
SC 3.70 5.22 6.04 5.23 4.50 3.85
Input 0.48 0.76 1.00 0.98 0.95 0.90
75.2/62.6
TC 6.12 8.51 9.70 8.30 7.02 5.91
SC 3.93 5.54 6.46 5.69 5.00 4.42
Input 0.48 0.77 1.01 1.00 0.97 0.92
80.6/66.2
TC 6.55 9.35 10.69 9.01 7.43 6.08
SC 4.25 6.06 7.04 6.12 5.26 4.50
Input 0.49 0.79 1.03 1.02 0.99 0.94
89.6/73.4
TC 6.67 9.86 11.75 10.36 8.95 7.62
SC 4.03 5.94 7.11 6.39 5.72 5.15
Input 0.49 0.79 1.05 1.05 1.03 0.99
012
(115v)
69.8/59
TC 5.94 8.63 10.38 8.52 5.60 4.68
SC 3.65 5.41 6.69 5.67 3.85 3.30
Input 0.58 0.97 1.35 1.29 0.99 0.94
75.2/62.6
TC 6.37 9.29 11.34 9.48 6.35 5.34
SC 3.88 5.74 7.16 6.16 4.29 3.79
Input 0.58 0.97 1.37 1.31 1.01 0.97
80.6/66.2
TC 6.82 10.21 12.50 10.30 6.71 5.50
SC 4.20 6.27 7.81 6.64 4.51 3.86
Input 0.59 0.99 1.39 1.34 1.03 0.99
89.6/73.4
TC 6.95 10.77 13.73 11.84 8.09 6.89
SC 3.98 6.15 7.88 6.93 4.90 4.41
Input 0.59 1.00 1.42 1.38 1.07 1.03
012
(208---230V)
69.8/59
TC 5.92 8.58 10.33 8.47 5.57 4.66
SC 3.59 5.32 6.57 5.57 3.79 3.25
Input 0.57 0.95 1.33 1.27 0.97 0.93
75.2/62.6
TC 6.34 9.24 11.28 9.43 6.32 5.32
SC 3.81 5.64 7.03 6.05 4.21 3.72
Input 0.58 0.96 1.35 1.30 1.00 0.95
80.6/66.2
TC 6.78 10.16 12.44 10.24 6.68 5.47
SC 4.13 6.17 7.67 6.52 4.43 3.79
Input 0.59 0.98 1.37 1.32 1.02 0.97
89.6/73.4
TC 6.91 10.72 13.66 11.79 8.05 6.85
SC 3.91 6.04 7.75 6.80 4.82 4.34
Input 0.58 0.98 1.40 1.36 1.06 1.02
018
69.8/59
TC 12.34 14.95 14.96 10.83 8.16 6.65
SC 7.90 9.77 10.05 7.52 5.85 4.89
Input 1.25 1.73 2.01 1.70 1.49 1.38
75.2/62.6
TC 13.22 16.10 16.34 12.06 9.25 7.59
SC 8.38 10.37 10.75 8.17 6.51 5.60
Input 1.25 1.74 2.03 1.73 1.52 1.42
80.6/66.2
TC 14.15 17.70 18.02 13.10 9.79 7.80
SC 9.08 11.33 11.73 8.80 6.85 5.71
Input 1.28 1.78 2.08 1.76 1.55 1.45
89.6/73.4
TC 14.42 18.66 19.80 15.07 11.79 9.78
SC 8.61 11.10 11.85 9.18 7.44 6.53
Input 1.26 1.79 2.12 1.82 1.62 1.52
022
69.8/59
TC 17.19 19.41 19.49 16.59 14.03 11.96
SC 11.68 13.45 13.88 12.21 10.67 9.33
Input 1.49 1.92 2.23 2.22 2.18 2.12
75.2/62.6
TC 18.43 20.91 21.28 18.47 15.90 13.66
SC 12.39 14.28 14.85 13.27 11.86 10.70
Input 1.49 1.93 2.26 2.26 2.23 2.18
80.6/66.2
TC 19.72 22.99 23.47 20.06 16.81 14.05
SC 13.43 15.61 16.20 14.29 12.49 10.90
Input 1.52 1.97 2.31 2.31 2.28 2.23
89.6/73.4
TC 20.09 24.24 25.79 23.07 20.26 17.61
SC 12.72 15.29 16.36 14.91 13.57 12.46
Input 1.50 1.98 2.35 2.38 2.37 2.33
LEGEND
DB --- Dry Bulb
W B --- W e t B u l b
TC --- Total Net Cooling Capacity (1000 Btu/hour)
SC --- Sensible Capacity (1000 Btu/hour)
I n pu t --- To t a l Po w e r ( k W )