Carrier MMK-AP0073H2UL Instrukcja Instalacji

Przeglądaj online lub pobierz Instrukcja Instalacji dla Klimatyzatory typu split Carrier MMK-AP0073H2UL. Carrier MMK-AP0073H2UL Installation manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 0
AIR CONDITIONER (MULTI TYPE)
Indoor Unit
Model name:
High Wall Type
MMK-AP0073H2UL
MMK-AP0093H2UL
MMK-AP0123H2UL
MMK-AP0153H2UL
MMK-AP0183H2UL
MMK-AP0243H2UL
Installation Manual
Installation Manual 1
English
Manuel d’installation 32
Français
+001111053901_00Ta.book Page 1 Monday, January 17, 2011 11:35 AM
Przeglądanie stron 0
1 2 3 4 5 6 ... 32 33

Podsumowanie treści

Strona 1 - Installation Manual

AIR CONDITIONER (MULTI TYPE)Indoor UnitModel name:High Wall TypeMMK-AP0073H2ULMMK-AP0093H2ULMMK-AP0123H2ULMMK-AP0153H2ULMMK-AP0183H2ULMMK-AP0243H2ULI

Strona 2 - Contents

High Wall TypeInstallation Manual–9– 5 Drain Piping Work Piping and drain hose forming* Apply heat-insulation for both refrigerant pipe and drain hos

Strona 3 - 1 Accessory Parts

High Wall TypeInstallation Manual–10– ENRemove the drains capClip the drain cap by needle-nose pliers and pull out.Fix the drains cap1) Insert a 4 mm

Strona 4 - 2 Precautions for Safety

High Wall TypeInstallation Manual–11– ▼ Bottom right or bottom left piping• After scribing slits of the front panel with a knife or a marking-off pin,

Strona 5

High Wall TypeInstallation Manual–12– EN6 Indoor Unit Fixing1. Pass the pipe through the hole in the wall, and hook the indoor unit on the installatio

Strona 6

High Wall TypeInstallation Manual–13– 8 Refrigerant Piping Refrigerant Piping1. Use copper pipe with 0.03” (0.8 mm) or more thickness. (In case pipe

Strona 7 -  Installation place

High Wall TypeInstallation Manual–14– ENTightening connectionCAUTION• Do not apply excessive torque. Otherwise, the nut may crack depending on the con

Strona 8 - 4 Installation of Indoor Unit

High Wall TypeInstallation Manual–15–  Wireless remote control A-B selectionTo use 2 wireless remote controls for the respective air conditioners, wh

Strona 9 - 3.3"(85 mm)

High Wall TypeInstallation Manual–16– EN9 Electrical ConnectionWARNING1. Use predefined wire and connect them certainly. Keep the connecting terminal

Strona 10 - 5 Drain Piping Work

High Wall TypeInstallation Manual–17– Power supply wire• Recommended wire diameter and wire length for power supply wire.Electric characteristicsContr

Strona 11 - Fix the drain hose

High Wall TypeInstallation Manual–18– EN Wiring between indoor and outdoor unitsNOTEAn outdoor unit connected with control wiring between indoor and

Strona 12 - 1.7” (43 mm)

–1– High Wall TypeInstallation ManualContents1 Accessory Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strona 13 - 7 Drainage

High Wall TypeInstallation Manual–19–  Wire ConnectionREQUIREMENT• Connect the wires matching the terminal numbers.Incorrect connection causes a trou

Strona 14 - 8 Refrigerant Piping

High Wall TypeInstallation Manual–20– EN5. Clamp the wires with the cord clamp.6. Install the clamp base with a screw.7. Remove the conduit cover.8. A

Strona 15 - Heat insulation

High Wall TypeInstallation Manual–21– 10 Applicable ControlsA wired remote control is necessary for this function. This function cannot be operate wit

Strona 16

High Wall TypeInstallation Manual–22– ENProcedure 2Each time button is pushed, indoor unit numbers in the control group change cyclically. Select th

Strona 17 - 9 Electrical Connection

High Wall TypeInstallation Manual–23–  Adjustment of air direction1. Using the remote control, change the up/down air direction by moving the horizon

Strona 18 - Remote control wiring

High Wall TypeInstallation Manual–24– EN11 Test Run▼ In case of wired remote control Before test run• Before turning on the circuit breaker, carry ou

Strona 19 - ▼ Wiring example

High Wall TypeInstallation Manual–25– ▼ In case of wireless remote control (Forced test operation is performed in a different way.)REQUIREMENT• For th

Strona 20 -  Wire Connection

High Wall TypeInstallation Manual–26– EN12 TroubleshootingA wired remote control is necessary for this function. This function cannot be operate with

Strona 21 -  Address setup

High Wall TypeInstallation Manual–27–  Check codes and parts to be checkedCheck methodOn the remote control (Wired remote control, Central control re

Strona 22 - 10 Applicable Controls

High Wall TypeInstallation Manual–28– ENE28 E28 Detected outdoor unit number Follower outdoor unit error I/FE31 E31 IPDU communication error I/FF01 —

Strona 23 - Procedure 6

High Wall TypeInstallation Manual–2– EN1 Accessory Parts Accessory parts<Others>Part name Q’ty ShapeInstallation plate 1Wireless remote control

Strona 24 -  Group control

High Wall TypeInstallation Manual–29– H05 H05 — TD1 miswiring I/FH06 H06 — Low pressure protective operation I/FH07 H07 — Oil level down detective pro

Strona 25 - 11 Test Run

High Wall TypeInstallation Manual–30– ENError detected by TCC-LINK central control deviceTCC-LINK : TOSHIBA Carrier Communication Link.P04 P0401: Comp

Strona 26 - High Wall Type

High Wall TypeInstallation Manual–31– WARNINGS ON REFRIGERANT LEAKAGECheck of Concentration LimitThe room in which the air conditioner is to be insta

Strona 27 - 12 Troubleshooting

1111053901 Confirmation of Indoor Unit SetupPrior to delivery to the customer, check the address and setup of the indoor unit, which has been installe

Strona 28 - Check code list

High Wall TypeInstallation Manual–3– 2 Precautions for SafetyInstalling, starting up, and servicing air-conditioning equipment can be hazardous due to

Strona 29

High Wall TypeInstallation Manual–4– EN• If refrigerant gas has leaked during the installation work, ventilate the room immediately.If the leaked refr

Strona 30

High Wall TypeInstallation Manual–5– 3 Selection of Installation PlaceWARNING• Install the air conditioner securely in a location where the base can s

Strona 31

High Wall TypeInstallation Manual–6– EN Installation diagram of Indoor and outdoor units Installation spaceThe indoor unit shall be installed so tha

Strona 32 - Important

High Wall TypeInstallation Manual–7–  Wireless remote control• A place where there are no obstacles such as a curtain that may block the signal from

Strona 33 - Indoor unit setup check sheet

High Wall TypeInstallation Manual–8– EN Cutting a hole and mounting installation plateCutting a holeIn case of installing the refrigerant pipes from

Komentarze do niniejszej Instrukcji