Test Descriptions
TEST_44 - CPD CDMA Release
TEST_44 - CPD CDMA Release
Description
This test performs a CDMA Base-station-initiated release.
1. A Service Option 2 (or 9) call is attempted, unless a call is already
connected. If the MSUT has not registered, the call attempt may be
unsuccessful and the error message “Failed to establish a call in test
<>” will be displayed. To correct this problem, perform the CPD
Registration test.
2. An attempt is made to end the call.
3. The average power measurement is monitored until its level reaches
-45 dBm or a timer expires. If the average power measurement
reaches -45 dBm or less, the call was successfully terminated.
4. The following measurement results are printed to the TESTS
(IBASIC Controller) screen:
Land Station Clear <YES/NO>
Pass/Fail Limits Used
•None
Parameters Used
9. CPD BID Number
11. CPD NID Number
12. CPD SID Number
18. RT Prot Std [0=95 1=95A 2=TSB74 3=ARIB]
19. RT Rate Set Selection [0=9600 1=14400]
22. RX RF Level for Signaling (dBm)