TCSNAC01, TCSNHP 01Non-- Programma ble ThermostatInstallation InstructionsA08147NOTE: Read the entire instruction manual before starting theinstallati
2NOTE: If 2 dashes (---- ) appear, your thermostat does not includethe outdoor temperature function or the function is not workingproperly. Check with
2Table 1 – Model Selection and Wiring Diagram ChartOUTDOOR UNITAIR CONDITIONER1 SpeedHEAT PUMP1 Speed1---Stage Furnace Model AC See Fig. ---2---Stage
3To enter the configuration mode:To enter Configuration Mode, hold the FAN button down forapproximately 15 seconds. After the 15 second period, Option
43. Press MODE button once. The SET icon will come on. Thedisplay now shows Option 07 setting.4. Use up and down buttons to move between availableOpti
5To Select:1. Enter configuration mode (if not already there).2. Use up and down buttons to display Option 21. The SETicon should be off.3. Press MODE
6Thermostat Fan Coil Heat PumpO/B OHeatWW WCoolYY YFanGG24VACRR RCommonCC C*A08163*Common connection not required if batteries are used.Fig. 3 -- HP T
7OPERATIONAL INFORMATIONFive--minute Compressor TimeguardThe cycle timer limits the number of times the heating or cooling equipment can be energized
8Copyright 2008 Carrier Corp. S 7310 W. Morris St. S Indianapolis, IN 46231 Printed in China Edition Da te: 03/08Manufacturer reserves the right to ch
TCSNAC01, TCSNHP 01Non-- Programma ble ThermostatHomeowner ’s GuideA08147CONGRATULATIONSINTELLIGENT, EASY TO USECongratulations on your purchase of a
Komentarze do niniejszej Instrukcji